The Rosemount 3144P Temperature Transmitter (available with HART or FOUNDATION fieldbus protocols) provides industry-leading accuracy, stability, and reliability.This Temperature Transmitter is designed with a dual-compartment, field-mount electromechanical configuration, protecting the transmitter against water intrusion and shielding it from harmful electromagnetic surges. A 5-year stability specification and an optional integral transient protector make the 3144P the most reliable temperature measurement instrument available. The Temperature Transmitter has the capability to accept single-sensor or dual-sensor inputs, which allows the transmitter to receive simultaneous inputs from two independent sensors. A dual-sensor configuration can be used for averaging temperatures, measuring differentials, providing a redundant temperature measurement, and taking advantage of key features, such as Hot Backup® and Sensor Drift Alert. Advanced diagnostics capabilities enable detection of sensor drift, potential thermocouple sensor or loop degradation, and enhanced insight into your processes and instrumentation. The 3144p Transmitter is available with MID certification for European Custody Transfer. Contact your salesman for more information.http://www.chinaguiding.com/Product/840197620.html
Features & Benefits of Rosemount 3144P
Single-sensor and dual-sensor input capability in one transmitter
Enhanced EMI rejection and filtering results in unmatched stability in process measurement
Safety Certified third party validation metrics per IEC61508 for Safety Instrumented Systems (SIS)
Industry-leading 5-year stability, which reduces maintenance costs
Hot Backup® and Sensor Drift Alert features improve measurement reliability over time
Transmitter-Sensor Matching eliminates sensor interchangeability error, which improves accuracy by 75%
http://www.chinaguiding.com/Product/2615485850.html
Dual-compartment housing provides the highest reliability in harsh environments
Integral LCD meter with large, easy-to-read display
Thermocouple Degradation Diagnostic enables the user to monitor the resistance of their thermocouple loop to anticipate sensor failure and
schedule preventative maintenance to avoid shutdowns
Minimum and Maximum Temperature Tracking allows the user to monitor the temperature of Sensor 1, Sensor 2, and their differential.
http://www.chinaguiding.com/Product/3187494235.html
Specifications of Rosemount 3144P Temperature Transmitter
Digital Accuracy ±0.10° C (±0.18° F) for Pt100 RTD
D/A Accuracy ±0.02% of span (Applies to HART/4-20 mA devices)
Ambient Temperature Effects 0.0015 °C (+0.001% of span for HART/4-20 mA devices) per 1.0 °C (1.8 °F) change in ambient for a Pt100 RTD
Stability (RTDs)
±0.1% of reading or 0.1° C, whichever is greater, for two years
±0.25% of reading or 0.25° C, whichever is greater, for five years
Input Two Independently Configured Inputs; 2-, 3-, and 4-wire RTD, and Ohm, Thermocouple, Millivolt
Output 4-20 mA/HART or FOUNDATION fieldbus signal
Supply Voltage 12.0 to 42.4 V dc (with 250 ohm load, 18.1 V dc is required)
http://www.chinaguiding.com/Product/3428695814.html