LOS ANGELES, CALIFORNIA. To find, eradicate, and remove toxic mold growth inside heating, ventilating and air conditioning (HVAC) equipment and ducts, Enviro Dangers announces the new HVAC Mold Removal Protocol™ for buildings in California, Nevada, Arizona, and USA.The protocol includes these ten steps:
1. Mold test both the outward air flow from each HVAC air supply duct register and all rooms and areas (including crawl space, basement, and attic) with either an air pump with Air-O-Cell mold sampling cassettes or Petri lab dishes with malt agar growth nutrient.
2. Mold test one outdoor location five feet beyond the building’s roof water drip edge as a control test against which to compare indoor mold lab results.
3. Have the mold tests and the outdoor control test analyzed by a certified mold laboratory for mold species identification and quantification.
4. If one or more of the indoor mold lab test results discovers more types of mold species and/or greater mold spore or mold colony counts, or if the indoor mold counts are especially high regardless of the outdoor test comparison, do the following mold remediation steps for the HVAC equipment and systems, along with the entire home or building.
5. With no persons, pets, or plants inside the building during the ozone treatment time and for two hours afterwards, inject high outputs of ozone gas from an ozone generator for six hours into the HVAC’s return air duct to eradicate HVAC mold spores, mold growth colonies, and bacteria. Then do at least four hours of ozone treatment separately in each room and area.
6. Have a qualified and experienced air duct cleaner scrub the insides of all HVAC ducts to remove deposited mold spores, mold colony growth, bacterial growth, and accumulated dust and dirt (mold food).
7. After the duct cleaning, do a second ozone gas treatment for another six hours inside all HVAC ducts, plus four more hours in each room or area.
8. After the second ozone treatment, use a fogging machine to fog an EPA-registered fungicide such as Tim-Bor into the HVAC equipment and ducts as an additional mold-killing step and to leave a protective coating on all HVAC interior surfaces to help prevent future mold growth.
9. Then repeat the mold testing steps 1 through 4 as described and explained above. Mold lab results will suggest whether the HVAC and building mold problems are now solved, or whether the above mold remediation steps need to be done again.
10. Do year-round preventative building maintenance to keep indoor humidity at less than 70% (above which humidity can cause widespread indoor mold growth), and regularly inspect the building to find and repair roof water leaks, siding water leaks, plumbing leaks, and water intrusion into the crawl space and basement.
To schedule the newly-launched Enviro Dangers HVAC Mold Removal Protocol™ for your home or other building in California, Las Vegas, Arizona, or nationwide USA, please visit Mold Consultants, phone 1-480-310-7970, or email phil@moldinspector.com.
(30)