The use of the expansion joint in Fluid Catalytic Cracking Unit (FCCU) service are exposed to high pressure, temperature , very aggressive media , large movement conditions. These are considered as highly engineered units and are considered as one of the complex and critical types of expansion joints manufactured. The design of these joints is complex because of the several reasons. These are as follows.
? These joints should be suitable to operate at high process temperatures.
? These joints must be resistant to erosion by catalyst.
? These joints must be resistant to stress corrosion cracking and corrosion during shutdown and operating condition.
? These joints should ensure adequate fatigue life
? These joints should have the capacity to absorb large movements.
? These joints ensure a good pressure resistance capacity while having a good flexibility.
The FCC technology involves high tech expansion joints and each technology provider has exclusive designs for these components.
FCCU Expansion Joint Types
There are typical types of expansion joints that are used in FCCU application. These are Restrained Universal, Pressure Balanced, Gimbal and Hinged. These are also categorized in the three major groups:
? Cold Wall
? Unlined
? Hot Wall
Cold Wall
In order to ensure the shell wall temperature does not exceed the allowed parameters, the cold wall units are refractory lined. The lining consists of high-density vibrocast and stainless steel anchors. They incorporate internal insulation made of bio ceramic fibre, a liner seal that keeps in place the insulation blankets while keeping the fluid particles out of the liner cavity.
One of main advantage of the cold wall design joints is that the pipe is insulated so it operates below the media temperature, joint movement and reduction in pipe growth.
To reduce the temperature, an insulation pillow is included. In order to prevent the bellow elements from dropping below the acid dew point, an external insulation is incorporated. This is the main reason of premature failure for bellows.
Hot Wall
The hot wall units incorporate the abrasion resistant lining, which includes castable materials and hex mesh. The lining requires a specific and controlled drying and it is not intended to be used as a thermal fence.
Unlined
The Unlined FCCU expansion joints usually do not convey catalyst. These joints can be exposed to very high temperatures. These joints do not require abrasion resistant lining. This type is generally used in the outlet and inlet air and transferring gases from the reactor.
Bellows
The most critical part of the expansion joints are bellows and can be single ply, redundant ply, multiply and generally incorporate an early warning system. The FCCU expansion joints generally incorporate two-ply tenable bellows where the ply is designed for full operating conditions. During service, if the hole develops in the inner ply, the outer ply takes over without exposing operators to increased risks for an unscheduled shutdown.
The two-ply testable bellows system makes the expansion joints friendlier and improves the reliability.
Thus, the expansion joints are one of the most reliable elements for FCCU unit.