OKY is leading EMI/EMC Filter developing company in Korea.Since 1992, we are developing EMI/EMC filters and suppling them to our customers.Also we developed power quality solutions, such as DVC (Dip-sag voltage compensator) and UPS.Recently, we expanded our business field into new and renewable energe,smart-grid electric vehicle, We hope to see you soon.
A short duration reduction in rms voltage caused by faults on the power system and starting of large loads, such as motors.Voltage sags are caused by abrupt increases in loads such as short circuits or faults, motors starting, or electric heaters turning on, or they are caused by abrupt increases in source impedance, typically caused by a loose connection. Voltage swells are almost always caused by an abrupt reduction in load on a circuit with a poor or damaged voltage regulator, although they can also be caused by a damaged or loose neutral connection.Voltage sags are the most common power disturbance. At a typical industrial site, it is not unusual to see several sags per year at the service entrance, and far more at equipment terminals.Voltage sags can arrive from the utility; however, in most cases, the majority of sags are generated inside a building. For example, in residential wiring, the most common cause of voltage sags is the starting current drawn by refrigerator and air conditioning motors.Sags do not generally disturb incandescent or fluorescent lighting. motors, or heaters. However, some electronic equipment lacks sufficient internal energy storage and, therefore, cannot ride through sags in the supply voltage. Equipment may be able to ride through very brief, deep sags, or it may be able to ride through longer but shallower sags.
We manufacture EMC/EMI products like D.C, A.C Single Phase, A.C 3Phase 4wire, Inverter Input, Inverter Output and power products like Single Phase DVC, Three Phase DVC, Automatic Transfer Switch, and Sag is momentary voltage drop phenomenon within one second. There are two causes why sag happen. First, natural reason such as lightning, storms, snow, heavy winds, or damage by wild animal and plant. Secondly artificial reason which is manly about input voltage drops by electrical overloading due to peripheral equipment usage.Sag(dip) of power supply can appear without pre-warning and usually last less than 0.4 seconds, and can dip the supply voltage down by 90%. Sag issues is now the most frequent quality problem in electrical power distribution.
UDS Is A Combination Product Of DVC And UPS
• developed against voltage sag as well as power interruption
Line Interactive Method
• Normally commercial power supplied,
however power interruption or Voltage sag happen,
the power charged in Super Capacitor of
DVC or Battery of UPS will be inverted.
Non-Down 24 Hours, 365 Days
•
When problem occurs in UDS, Maintenance available without Equipment Down DVC & UPS connected in parallel structure. Mutual Auto Transfer Switching Function between DVC & UPS. When trouble happens in DVC or UPS, Emergency Bypass function will be activated